| home / past projects / INTERNATIONAL GAME TECHNOLOGIES | |
|
Project: 3 METER CERTIFIED EMC CHAMBER Client: INTERNATIONAL GAME TECHNOLOGIES, Reno, NV Contact: Paul Crozier (702) 686-1222 Size/Description: 16'W. x 26'L. x 20'H. Lehman Chambers designed and constructed this 3 meter EMC chamber in accordance with ANSI C63.4 and IEC 10000-4-3 for certified emissions and immunity testing. The facility utilizes a FM200 fire protection to eliminate water damage associated with pre-action sprinklers. The facility has a complete CCTV system and the raised access floor for the flush installation of a 1.5 meter diameter turntable. ![]() Lehman Chambers Scope of Work: - design/engineering and computer modeling - working drawings and submittals - install modular panel system - install mechanical/electrical system - install fire protection system - install ferrite tile absorber material - install pyramidal urethane foam absorber material - testing and certification Status: Operational-Listed with FCC |
|
Questions or comments? email: sales@cuminglehman.com |