Project: 3 METER EMC CHAMBER

Client: CRITERION TECHNOLOGY, Rollinsville, CO


Size/Description: 18'W. x 28'L. x 11'H.
3M Immunity Test Facility w/ 3.0mx1.5m UFA

Criterion had unique requirements for their chamber, in that they needed an increased Uniform Field Area for testing large products for immunity. Complicating the design task was the requirement for the room to perform up to 3GHz. Cuming-Lehman Chambers utilized 3D-FDTD modeling to come up with a feasible design, satisfying Criterion's technical requirements, while still maintaining their budget.



Cuming-Lehman Chambers Scope of Work:

    - design/engineering and computer modeling
    - working drawings and submittals
    - install modular panel system
    - install mechanical/electrical system
    - install ferrite tile absorber material
    - install pyramidal urethane foam absorber material
    - install turntable and floor tile slide
    - testing and certification

Status: Operational